Standard Specifications— Fibersorb™ Acoustical Curtain Systems |
| Absorber and Barrier Curtain System Use Factors Summary | |
|
Curtain Type
|
Use Factors
|
|
SC
Single-Layer Blocking |
Total and partial enclosures, shrouds, and hoods. Noise source on one side. Noise reduction objectives: 10-15 dBA. (Actual noise reduction can vary with application and may exceed these values.) Maximum curl, tear abuse, resistance. |
|
SC-2
Single-Layer Blocking |
Total and partial enclosures, shrouds, and hoods. Noise source on one side. Best product combining the durability of a 1 lb/sq ft reinforced acoustical barrier with a 2-inch-thick faced fiberglass absorber offering maximum performance (STC=32, NRC=0.85). Noise reduction objectives: 15-20 dBA. |
|
DC
Double-Layer Blocking |
Separator walls and divider partitions. Noise source on both sides. Noise reduction objectives: 10-15 dBA. (Actual noise reduction can vary with application and may exceed these values.) Passes ASTM E84-84a; class 1 fire rating. |
|
DC-2
Double-Layer Blocking |
Separator walls and divider partitions. Noise source on both sides. Maximum performance (STC=33, NRC=0.75). Noise reduction objectives: 15-20 dBA. (Actual noise reduction can vary with application and may exceed these values.) Barrier septum 1 lb/sq ft. |
| Sound Transmission Loss (dB) | ||||||||
Curtain Type
|
Approx. Product
Weight (lb/sq ft) |
1/3 Octave Band Center Frequency (Hz)
|
||||||
|
125
|
250
|
500
|
1,000
|
2,000
|
4,000
|
Sound
Transmission Coefficient |
||
DC Double-Layer Blocking |
1.5
|
12
|
16
|
27
|
40
|
44
|
47
|
29
|
DC-2
Double-Layer Blocking |
2.5
|
19
|
22
|
28
|
40
|
56
|
61
|
33
|
SC
Single-Layer Blocking |
1.3
|
11
|
16
|
24
|
30
|
39
|
43
|
27
|
SC-2
Single-Layer Blocking |
1.5
|
13
|
20
|
29
|
40
|
50
|
55
|
32
|
TC
Transparent |
1.0
|
13
|
17
|
22
|
26
|
32
|
37
|
26
|
AC
Absorption |
0.4
|
6
|
11
|
15
|
20
|
25 |
32
|
19
|
| Sound Absorption Coefficients | ||||||||
Curtain Type
|
Approx. Product
Thickness (inches) |
1/3 Octave Band Center Frequency (Hz)
|
||||||
125
|
250
|
500
|
1,000
|
2,000
|
4,000
|
Noise
Reduction Coefficient |
||
DC
Double-Layer Blocking |
2
|
0.38
|
0.89
|
0.82
|
0.76
|
0.53
|
0.35
|
0.75
|
SC
Single-Layer Blocking |
1
|
0.12
|
0.47
|
0.85
|
0.84
|
0.64
|
0.62
|
0.70
|
SC-2
Single-Layer Blocking |
2
|
0.19
|
0.99
|
0.96
|
0.80
|
0.57
|
0.33
|
0.85
|
AC
Absorption |
2
|
0.19
|
0.99
|
0.96
|
0.80
|
0.57
|
0.33
|
0.85
|
AC-4
Absorption |
4
|
0.21
|
0.89
|
1.09
|
1.17
|
1.13
|
1.07
|
1.05
|
|
To
find out more about our acoustical products and services,
contact us at: sales@mcgillairsilence.com Or call us at: 614/829-1200, Fax: 614/829-1488. |
|